Weighing instrument LX-160

LX-160 type instrument is a high-performance belt scale control instrument developed and designed with reference to imported similar instruments. The instrument adopts imported 32-bit industrial CPU, 10 × 5 The man-machine interface with Chinese character LCD display and digital and functional compound key operation has multiple groups of mutually isolated input and output interfaces, and each interface has multiple anti-interference measures. In terms of functions, this instrument is characterized by practicality, intelligence, multifunction and ease of use, and is a kind of instrument with high cost performance among similar domestic products. It is suitable for the control of various continuous batching scales.

24-hour hotline:+86-13905362756

Product Details

Functional features

It adopts 32-bit ARM CPU with high reliability and fast running speed.

The intelligent control algorithm and intelligent function processing greatly simplify the parameter setting and make the instrument operation very simple.

The standard modbus communication interface is convenient for connection with other systems.

Multi key operation, convenient and fast.

The specially designed power supply circuit not only has high reliability, but also has a wider voltage range. The utility model overcomes the disadvantage that the common switching power supply is only suitable for low voltage operation, but not suitable for high voltage power supply operation higher than 260V.

Double sets of data storage circuits, all parameters are backed up and stored, and can be automatically recovered once the data is disturbed. At the same time, the instrument also has the functions of restoring factory settings, restoring backup, etc.

The ADC circuit with better performance is adopted, which not only has high speed and precision, but also avoids the disadvantage that the common programmable ADC circuit cannot operate normally due to the loss of interference configuration files.

The pulse shaping circuit is added to the speed measurement input, which can make the speed measurement result more accurate and stable.

The instrument sets more function modes. The instrument includes single speed regulation mode, double speed regulation mode, constant speed mode, metering mode, reamer scale mode, punching plate flowmeter mode, etc. In addition, feedforward control realized by analog output can be used to realize speed regulation operation without speed measuring device.

Flexible control mode. The instrument can set the flow rate and start the instrument through keyboard, communication or interface. In addition, the metering mode can be started at an optional speed.

In the form of punched plate flowmeter, the instrument has 4-point linearization processing.

It has volume operation mode. When the speed sensor or load sensor fails, the instrument can refer to the empirical data under normal conditions for open-loop control.

Run the function manually. This function can facilitate system testing.

The instrument has parameter setting function, interface test function, calibration function (zero calibration, chain code calibration and physical calibration), parameter backup and recovery function, etc. It supports keyboard to modify zero point and coefficient directly.

The V2.0 version adds bilingual display, which can be displayed in Chinese and English through parameter selection.


technical parameter

Comprehensive metering accuracy of instrument: 0.03%

Analog input channel. 2-channel 16 bit ADC, conversion speed is 240 times/s, and active filter with cut-off frequency of 2-5Hz is adopted. Channel 1 is the input channel of the load sensor, with the sensor supply voltage of 5 or 10V and 6-wire or 4-wire wiring. Channel 2 is an external flow setting channel, which can input O-20mA current signal with input impedance of 120 Ω.

Analog output channel. Three 16 bit analog output channels, with output signal of O-20mA and load driving capacity of 500 Ω. Analog output signal is used for main control output, instantaneous flow output and auxiliary control output (dual speed regulation control).

Switch output. Six channels of switching value output, using high-power triode OC output, can drive 100V/1A DC load. Switching value output includes startup, readiness, operation, cumulative pulse, alarm output, volume output, etc.

Switch input. 4 channels of switching value input channels, which are valid by pull-down input. Passive point of relay and input equipment of OC output mode can be used. Switch input can be used for speed measurement pulse input, startup, alarm reset, etc.

Flow unit: t/h, kg/h, or kg/m. Flow display range: O-99999

Weight unit: t, kg

Cumulative weight display range 0-999999999

Working power supply: 160-300V 50Hz, 10W

Working environment: - 10-50c, 10-95% RH (no condensation)

20161118093220_9705.jpg

contact
customer service

+86-13905362756
Welcome to call

WeChat
communicate

WeChat communication by scanning code
TOP
X

Screenshot, WeChat QR code

wechat number:+86-13905362756

(Click WeChat copy to add friends)

Open WeChat

WeChat has been copied, please open WeChat to add details!